Inverter-plus

Powered by  

Features:
• Super energy-saving and Eco-friendly
• Super Silent
• Smartphone APP control remotely(optional)
• Automatic defrosting
• Soft start 
• Operating air temperature -7℃~43℃
 
Applications:
• Pool size range 15m³~160m³
• Indoor and outdoor pools


  • Details
  • Tech info of R32
  • Tech info of R410A
  • Download
• Super energy-saving: Half running cost

AVERAGE COP 11 at 50% capacity, COP 16 at 20% capacity (Air 26℃/ Water 26℃/ Humidity 80%)
                                                                                                                       —— Certified by TÜV Rheinland
 
(COP means Coefficient of Performance it is a ratio of heating capacity to power consumption)

Half running cost principle (in 180 days swimming season)
In the first 5 days a Inverter-plus pool heat pump runs at 100% capacity and heats up the pool to the set temperature. In the next 175 days, it runs at AVERAGE 50% capacity by AVERAGE COP 11 to maintain the desired pool 
temperature. So the AVERAGE COP is double of On/Off heat pump.


 
COP Comparison between Inverter-plus pool heat pump VS Traditional On/Off heat pump
(in 180 days swimming season, e.g.13.5kW at Air 26°C/ Water 26°C/ Humidity 80%)


 

 



AVERAGE power consumption
(in 180 days swimming season,e.g.13.5kw at Air 26℃/Water 26℃/ Humidity 80%)


 



 AVERAGE 10 Times Quieter
When maintaining pool temperature at AVERAGE 50% capacity, AVERAGE sound pressure of a Inverter-plus pool heat pump can bring you 10 times quieter swimming environment and more friendly neighborhood than an On/Off pool heater. 


 


 

AVERAGE sound pressure at 1m dB(A)


• Soft Start
When Inverter-plus pool heat pump turns on, the current will start from 0A and go up slowly to rated current in 2 minutes. It will not affect the house electricity system, while the frequent start current of On/Off heat pump is 5 times of rated current, it is a burden to the electricity system.

 
 
 

SPECIFICATIONS OF INVERTER-PLUS HEATPUMP
Model IPHR15 IPHR20 IPHR26 IPHR33 IPHR40 IPHR45 IPHR55 IPHR70 IPHR70T IPHR100T
Advised pool volume  (m3) 15~30 20~40 25~45 30~55 35~65 40~75 50~95 65~120 65~120 90~160
Operating air temperature (℃)  -7~43
Performance Condition: Air 26°C, Water 26°C, Humidity 80%
Heating capacity (kW)                     6.5 8.5 10.5 13.0 15.0 17.5 20.5 27.5 27.3 35.8
COP  14.7~6.0 14.8~7.4 15.0~7.4 15.4~7.3 15.5~6.7 15.8~6.2 15.3~6.0 15.4~6.5 15.3~6.5 15.6~5.8
COP at 50% capacity  10.5 10.9 11.0 11.0 10.9 11.1 10.7 11.2 11.2 10.9
Performance Condition: Air 15°C, Water 26°C, Humidity 70%
Heating capacity (kW)                     4.8 6.3 7.3 8.7 10.5 11.5 14.0 18.0 18.0 24.5
COP                  7.3~4.5 7.4~5.0 7.7~4.8 7.7~4.8 7.8~4.6 7.8~4.5 7.7~4.4 8.1~4.8 8.1~4.8 8.0~4.7
COP at 50% capacity  6.3 6.6 6.8 6.8 6.6 6.4 6.3 6.8 6.8 7.0
 
Sound pressure at 1m  dB(A) 37.8~47.2 38.8~48.2 38.6~49.9 42.1~50.7 41.3~55.0 43.1~53.8 40.9~54.2 43.5~54.9 43.5~54.9 42.6~54.7
Sound pressure of 50% capacity at 1m dB(A) 40.1 41.4 43.3 45.7 46.5 46.5 46.4 48.4 48.4 45.8
Sound pressure at 10m dB(A) 17.8~27.2 18.8~28.2 18.6~29.9 22.1~30.7 21.3~35.0 23.1~33.8 20.9~34.2 23.5~34.9 23.5~34.9 22.6~34.7
Compressor Twin-rotary Mitsubishi DC-inverter 
Heat exchanger Spiral titanium tube in PVC
Casing Aluminum-alloy
Power supply  230V/1 Ph/50Hz 400V/3 Ph/50Hz
Rated input power  at air 15°C (kW)  0.13~1.06 0.17~1.2 0.19~1.5 0.23~1.81 0.27~2.2 0.30~2.6 0.36~3.18 0.55~3.8 0.55~3.9 0.61~5.2
Rated input current  at air 15°C  (A) 0.56~4.60 0.74~5.2 0.83~6.5 1.00~7.87 1.17~9.6 1.3~11.3 1.57~13.8 2.4~16.5 0.79~5.6 0.88~7.4
Net dimension LxWxH (mm) 894×359×648 894×359×648 894×359×648 954×359×648 954×359×648 954×429×648 954×429×755 1084×429×948 1084×429×948 1154×539×948
Net weight    (kg) 42 45 49 50 52 63 68 90 93 120
Qty per 20'FT / 40'HQ    (sets) 102/216 102/216 102/216 90/198 90/198 78/165 52/165 44/100 44/100 34/72

←Please drag to see more on small size devices→
SPECIFICATIONS OF INVERTER-PLUS HEATPUMP
Model IPH15 IPH20 IPH25 IPH30 IPH35 IPH45 IPH55 IPH70 IPH70T IPH100T
Advised pool volume  (m3) 15~30 20~40 25~45 30~55 35~65 40~75 50~95 65~120 65~120 90~160
Operating air temperature (℃)  -7~43
Performance Condition: Air 26°C, Water 26°C, Humidity 80%
Heating capacity (kW)       6.5 8.1 10.0 12.1 13.5 17.5 21.0 27.5 27.3 35.5
COP  15.8~7.4 15.5~7.4 16.2~7.3 15.6~6.0 16.3~6.7 16.6~6.2 16.1~6.0 16.2~6.5 16.1~6.5 16.5~5.8
COP at 50% capacity 11.3 11.2 11.3 10.8 11.2 11.4 11.0 11.5 11.5 11.2
Performance Condition: Air 15°C, Water 26°C, Humidity 70%
Heating capacity (kW)                    4.8 6.0 7.0 8.1 9.5 11.5 14.5 18.0 18.0 24.2
COP                 8.1~4.8 7.7~5.0 8.1~4.8 7.8~4.5 8.2~4.6 8.2~4.5 8.1~4.4 8.5~4.8 8.5~4.8 8.4~4.7
COP at 50% capacity 7.0 6.8 7.0 6.5 6.8 6.6 6.5 7.0 7.0 7.2
Sound pressure at 1m  dB(A) 37.8~47.2 38.8~48.2 38.6~49.9 42.1~50.7 41.3~54.0 43.1~53.8 40.9~54.2 43.5~54.9 43.5~54.9 42.6~54.7
Sound pressure of 50% capacity at 1m dB(A) 40.1 41.4 43.3 45.7 46.0 46.5 46.4 48.4 48.4 45.8
Sound pressure at 10m dB(A) 17.8~27.2 18.8~28.2 18.6~29.9 22.1~30.7 21.3~34.0 23.1~33.8 20.9~34.2 23.5~34.9 23.5~34.9 22.6~34.7
Compressor Twin-rotary Mitsubishi DC-inverter 
Heat exchanger Spiral titanium tube in PVC
Casing Aluminum-alloy
Power supply  230V/1 Ph/50Hz 400V/3 Ph/50Hz
Rated input power  at air 15°C (kW)  0.12~0.94 0.16~1.2 0.21~1.4 0.24~1.8 0.27~2.1 0.3~2.6 0.36~3.3 0.53~3.8 0.53~3.9 0.63~5.15
Rated input current  at air 15°C  (A) 0.52~4.1 0.7~5.2 0.91~6.1 1.04~7.8 1.17~9.1 1.3~11.3 1.57~14.3 2.3~16.5 0.76~5.6 0.91~7.4
Net dimension LxWxH (mm) 894×359×648 894×359×648 894×359×648 954×359×648 954×359×648 954×429×648 954×429×755 1084×429×948 1084×429×948 1154×539×948
Net weight    (kg) 42 45 49 50 52 63 68 90 93 117
Qty per 20'FT / 40'HQ    (sets) 102/216 102/216 102/216 90/198 90/198 78/165 52/165 44/100 44/100 34/72

←Please drag to see more on small size devices→